Adding items ​

Each kind of item is added in the view that owns it:

ItemWhereHow
RackAny view (Rack Elevation shows it)Add Rack or 0
Server, switch, PDURack Elevation, Port Mapping, Power Budget1, 3, 4, then click
NIC / port group / load bankPort Mapping, or the side panel5, then click a device
PortSide panel+ Port on a NIC
Network cablePort MappingC, then click two ports
Power inletPower Budget, or the side panel5, then click a device
Power cordPower BudgetC, then click an outlet and an inlet
BondSide panel, on a portBond → + New bond
Label (tag)Side panel, on a device or cableLabels box
Template (model)Materials, or the catalog bar's +See Materials editor

Anything can also be added as text in the DSL editor.

Racks ​

Click Add Rack in the Rack Elevation toolbar, or press 0. The new rack is Rack N, 36U, in row 1; select it to change its label, height and row in the side panel.

Copy a whole rack

If a rack is selected when you add one, the new rack copies it: same height and row, the next label, and a copy of every device in it (with their NICs, ports and bonds, but not their cables). It is the fastest way to build ten identical racks.

Servers, switches and PDUs ​

  1. Pick the tool: Server (1), Switch (3) or PDU (4).
  2. Optionally pick a template in the catalog bar at the bottom. With no template, the device gets a default layout:
    • server: NIC eth0 with 2 × 25G SFP28 ports, and two power inlets;
    • switch: port group data with 32 × 100G QSFP28, mgmt with one RJ45, and two inlets;
    • PDU: banks bank1 and bank2, each 8 × C13 outlets behind a 20 A breaker.
  3. Click where it goes:
    • Rack Elevation — move over a rack. The preview is green where the device fits and red (No space) where it doesn't. Click to place it. Clicks outside a rack do nothing.
    • Port Mapping / Power Budget — click anywhere on the canvas. The device is unracked until you give it a rack (see Editing items).
  4. The tool stays on, so you can keep clicking. Press Esc or V when done.

Several servers at once. With the Server tool, press + / − to place N servers per click. In a rack they stack downward from where you click (the preview shows N × NU); on the canvas they stack vertically.

Clone mode. If a device of the same kind is selected when you click, the new device is a copy of it — same template, NICs, ports, bonds and labels, with the label's number counted up (node-07 → node-08). The cursor turns multicoloured to show it. Clear the selection (Esc) to place from the catalog instead.

NICs, port groups and load banks ​

  • On the canvas (Port Mapping): press 5 and click a server. It gets a new NIC with two ports, or one built from the NIC template selected in the catalog bar. Clicking a PDU adds a load bank. The tool then returns to Select.
  • In the side panel: select the device, open Edit device, and click + NIC (+ Port Group on a switch, + Bank on a PDU).

Devices placed from a template get their NICs from the template; change the template in Materials instead.

Ports ​

Select a NIC (click its label on the canvas), or open Edit device in the device's panel and expand the NIC's row. Click + Port (+ Outlet on a PDU bank). Set each port's speed and connector in its chip.

Network cables ​

  1. Open Port Mapping and press C (Cable). Optionally pick a cable template in the catalog bar — the new cable will use it.
  2. Click a free port; it turns yellow and a line follows the pointer.
  3. Click the port at the other end. The cable is created.

Click on empty canvas or press Esc to cancel a cable halfway. A port that already has a cable, or that cannot take this one, shows a not-allowed cursor.

Several cables at once. Press + to draw N cables per click (shown as ×N next to the line). Click a start port and an end port: the app connects N consecutive free ports of each NIC, in order. It refuses if either side doesn't have N free ports in a row.

Breakout cables. To cable the lanes of a split switch port, first split it: select the port and set Breakout to 2× or 4×. The port is drawn as lanes. With the Cable tool, click a lane to use it, or the port to take its first free lane.

Power inlets and power cords ​

  1. Open Power Budget. Network cables are hidden here by default; power cords are shown.
  2. Press 5 (Power inlet) and click a device to give it an inlet (PSU1, PSU2…). Or add inlets in the side panel with + Inlet, or in the device's template.
  3. Press C (Power cord). Click a PDU outlet, then a device inlet. Both ends must be power connectors, and one must be a PDU outlet.

The legend updates as you go: outlets in use per PDU, the load against the PDU's capacity, and how many inlets are still unfed.

Bonds ​

Select one of the member ports. In its panel, set Bond to + New bond. Name the bond and choose its mode (lacp, static or active-backup). Then select each other member port and choose the bond from its Bond list. Bonded ports have a purple outline.

A bond can only join ports of the same device, and breakout ports can't be members.

Labels ​

Select one or more devices (or cables). In the panel's Labels box, type a label and press Enter, or pick an existing one. See Filtering by label.